三、 性能數據
1)重復性精度
表:5系NCM前驅體混合樣重復性測試
單位:%
| 樣品名稱 |
次數 |
Li |
Ni |
Co |
Mn |
5系樣3 |
1 |
5.38 |
25.33 |
5.41 |
13.62 |
| 2 |
5.40 |
25.28 |
5.40 |
13.62 |
| 3 |
5.41 |
25.27 |
5.39 |
13.61 |
| 4 |
5.39 |
25.30 |
5.39 |
13.64 |
| 5 |
5.39 |
25.29 |
5.41 |
13.65 |
| 6 |
5.36 |
25.37 |
5.41 |
13.66 |
| 7 |
5.37 |
25.34 |
5.40 |
13.64 |
| AVERAGE |
5.39 |
25.31 |
5.40 |
13.63 |
| RSD |
0.32% |
0.14% |
0.17% |
0.13% |
說明:對于混合均勻的NCM正極材料,7次平行制樣,單波長激發-能量色散X射線熒光光譜儀PHECDA-ECO與 Holospec FP 2.0 測定,Li- RSD<0.35%,Ni/Co/Mn- RSD<0.2%。
2)準確性對比
表:NCM與NCA實驗室分析方法準確度對比
單位:%
| NCM正極材料 |
| 樣品名稱 |
Li(%) |
Ni(%) |
Co(%) |
Mn(%) |
| 測定值 |
HS XRF |
測定值 |
HS XRF |
測定值 |
HS XRF |
測定值 |
HS XRF |
| L-1 |
5.34 |
5.37 |
25.12 |
25.11 |
5.42 |
5.42 |
13.88 |
13.88 |
| L-2 |
5.40 |
5.36 |
25.04 |
25.09 |
5.40 |
5.39 |
13.84 |
13.87 |
| L-3 |
5.46 |
5.41 |
24.98 |
25.05 |
5.39 |
5.40 |
13.80 |
13.85 |
| 5系-1 |
4.55 |
4.56 |
26.88 |
26.83 |
5.75 |
5.78 |
14.45 |
14.47 |
| 5系-3 |
5.35 |
5.34 |
25.42 |
25.40 |
5.43 |
5.44 |
13.67 |
13.65 |
| 8系-3 |
5.31 |
5.29 |
35.42 |
35.50 |
4.85 |
4.87 |
2.44 |
2.42 |
| 8系-8 |
6.03 |
6.05 |
33.17 |
33.11 |
4.55 |
4.54 |
2.28 |
2.29 |
| NCA正極材料 |
| 樣品名稱 |
Li(%) |
Ni(%) |
Co(%) |
Al(%) |
| 測定值 |
HS XRF |
測定值 |
HS XRF |
測定值 |
HS XRF |
測定值 |
HS XRF |
| H-1 |
5.21 |
5.20 |
37.72 |
37.75 |
4.06 |
4.05 |
5.41 |
5.35 |
| H-2 |
5.29 |
5.34 |
37.42 |
37.35 |
4.04 |
4.01 |
5.36 |
5.37 |
| H-3 |
5.41 |
5.37 |
36.98 |
37.12 |
3.98 |
4.02 |
5.30 |
5.34 |
| 9系-3 |
5.33 |
5.31 |
37.90 |
37.89 |
4.11 |
4.13 |
- |
- |
說明:1.樣品由前驅體相應比例均勻混合制樣;
2. 采用準確定值樣品建立校正曲線,與化學法對比,Li測試偏差<0.05%,Ni/Co/Mn測試偏差<0.05%。
四、 特點優勢
速度快
采用直接裝杯壓實或壓片制樣,單個分析時間3分鐘;
重復性精度高
Li RSD~0.3%;Ni\Co\Mn RSD優于0.2%;
準確度
采用經嚴苛定量同類型樣品校正,Li準確度偏差<0.03%;
元素分析范圍寬
主量元素(Li、Ni、Co、Mn、Al、P、Fe)和雜質元素同步分析;
分析成本低
樣品分析成本小于10元/個;
樣品適應范圍寬
從前驅體、正極材料到涂布層,提供完整元素分析解決方案;
五、 測試流程
A. 壓片制樣
B. 粉末壓實制樣